Chen Qi e77d45609a oe_syslog.py: fix for syslog-ng
When using syslog-ng as the syslog provider, oe_syslog test case fails
because it cannot find the syslog daemon. This is because it greps for
'syslogd' but syslog-ng's daemon is 'syslog-ng'. So fix it to check both
'syslogd' and 'syslog-ng'.

Also, when the test case fails, what I get is:
| AssertionError: 1 != 0 : No syslogd process; ps output:
<empty here>

This does not help user. The output is actually from the 'PS | GREP' command.
And when the 'PS | GREP' command fails, the output is always empty. So also fix
this problem. After the change, it looks like:
| AssertionError: False is not true : No syslog daemon process; ps output:
|   PID USER       VSZ STAT COMMAND
|     1 root     16476 S    {systemd} /sbin/init
|     2 root         0 SW   [kthreadd]
|     3 root         0 IW   [kworker/0:0]
...

(From OE-Core rev: b180fbd9d93db1c6351e183fbc08fc81cdc240c0)

Signed-off-by: Chen Qi <Qi.Chen@windriver.com>
Signed-off-by: Richard Purdie <richard.purdie@linuxfoundation.org>
2018-08-08 10:51:59 +01:00
2018-08-08 10:51:59 +01:00
2014-01-02 12:58:54 +00:00
2018-02-24 10:31:45 +00:00

QEMU Emulation Targets
======================

To simplify development, the build system supports building images to
work with the QEMU emulator in system emulation mode. Several architectures
are currently supported in 32 and 64 bit variants:

  * ARM (qemuarm + qemuarm64)
  * x86 (qemux86 + qemux86-64)
  * PowerPC (qemuppc only)
  * MIPS (qemumips + qemumips64)

Use of the QEMU images is covered in the Yocto Project Reference Manual.
The appropriate MACHINE variable value corresponding to the target is given
in brackets.
Description
No description provided
Readme 249 MiB